Hydrazine
www.chemetrics.com | 1-800-356-3072
Method
Visual Kits
References: ASTM D 1385-01, Hydrazine in Water. L.
C. Thomas and G. J. Chamberlin, Colorimetric Chemical Range: 0-50 ppb
Analytical Methods, 8
th
ed., pp. 194-195, Method I
MDL: 2 ppb / Method: PDMAB
(1974).
Cat#
ULR CHEMets Kit K-5011
Hydrazine is a powerful reducing agent that is used
in various chemical processes and in boiler water as
ULR CHEMets Refill, 30 ampoules R-5011
an oxygen scavenger. To control corrosion, residual
Comparator, Shelf-life 2 years:
0, 2, 5, 10, 20, 30, 40, 50 ppb C-5011
hydrazine typically is maintained in the 0.05 to 0.1
Kit comes in a plastic case and contains everything needed to perform 30
mg/L range. Higher levels may be used to guard
tests: Refill, Comparator, 25 mL sample cup, instructions, and MSDS.
against corrosion when the boiler is out of service for
an extended period.
Range: 0-0.5 ppm
MDL: 0.005 ppm / Method: PDMAB
CHEMetrics’ hydrazine test kits employ the PDMAB,
paradimethylaminobenzaldehyde chemistry. PDMAB in
Cat#
acid solution reacts with hydrazine to form a yellow
CHEMets Kit K-5005
product. Results are expressed as ppm (mg/L) N
CHEMets Refill, 30 ampoules R-5005
2
H
4
.
Comparator, Shelf-life 2 years:
0, 0.01, 0.03, 0.05, 0.07, 0.1, 0.3, 0.5 ppm C-5005
Kit comes in a plastic case and contains everything needed to perform 30
tests: Refill, Comparator, 25 mL sample cup, instructions, and MSDS.
Range: 0-12.5 ppm
MDL: 0.25 ppm / Method: PDMAB
Cat#
VACUettes Kit K-5005D
VACUettes Refill, 30 ampoules R-5005D
Comparator, Shelf-life 2 years:
0, 0.25, 0.75, 1.25, 1.75, 2.5, 7.5, 12.5 ppm C-5005D
Kit comes in a plastic case and contains everything needed to perform 30
tests (except distilled water): Refill, Comparator, dilutor snapper cup, micro
test tube, instructions, and MSDS.
Range: 0-25 ppm
MDL: 0.5 ppm / Method: PDMAB
Cat#
VACUettes Kit K-5005A
VACUettes Refill, 30 ampoules R-5005A
Comparator, Shelf-life 2 years:
0, 0.5, 1.5, 2.5, 3.5, 5, 15, 25 ppm C-5005A
Kit comes in a plastic case and contains everything needed to perform 30
tests (except distilled water): Refill, Comparator, dilutor snapper cup, micro
test tube, instructions, and MSDS.
44
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88