www.chemetrics.com | 1-800-356-3072
Range: 0-60 & 60-300 ppm Range: 2.5-12% as NaOCl
MDL: 10 ppm / Method: DDPD MDL: 2.5% / Method: DDPD
Cat# Cat#
Chlorine (free & total) VACUettes Kit K-2505A Chlorine (hypochlorite) VACUettes Kit K-5812
VACUettes Refill, 30 ampoules R-2505A VACUettes Refill, 30 ampoules R-5812
Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years A-2500
1
Comparator, Shelf-life 2 years:
2.5, 3.5, 4.5, 6.0, 7.0, 8.5, 9.5, 10.5, 12.0% C-5812
Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-2501
1
Kit comes in a plastic case and contains everything needed to perform 30 tests
Low Range Comparator, Shelf-life 2 years:
(except distilled water): Refill, Comparator, 25 mL sample cup, dilutor snapper
0, 10, 15, 20, 30, 40, 50, 60 ppm C-2501A
cup, 1.0 mL syringe, micro test tube, instructions, and MSDS.
High Range Comparator, Shelf-life 2 years:
60, 90, 120, 150, 175, 200, 225, 250, 300 ppm C-2505A
Kit comes in a plastic case and contains everything needed to perform 30 tests
(except distilled water): Refill, Low and High Range Comparators, Activator
Instrumental Kits
Solution, Neutralizer Solution, dilutor snapper cup, micro test tube, instructions,
and MSDS.
V-2000 Multi-Analyte Photometer
(See page 12 for instrumental features)
Range: 0-120 & 120-600 ppm
MDL: 20 ppm / Method: DDPD
Range: 0.40-5.00 ppm
Cat#
Method: DPD
Chlorine (free & total) VACUettes Kit K-2505B
Cat#
VACUettes Refill, 30 ampoules R-2505B
Chlorine (free) Vacu-vials Kit (USEPA Approved) K-2523
Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years A-2500
1
Kit comes in a cardboard box and contains everything needed to perform
Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-2501
1 30 tests: thirty ampoules, 25 mL sample cup, ampoule blank, instructions,
calibration table, and MSDS.
Low Range Comparator, Shelf-life 2 years:
0, 20, 30, 40, 60, 80, 100, 120 ppm C-2501B
Range: 0.40-5.00 ppm
High Range Comparator, Shelf-life 2 years:
Method: DPD
120, 180, 240, 300, 350, 400, 450, 500, 600 ppm C-2505B
Cat#
Kit comes in a plastic case and contains everything needed to perform 30 tests
(except distilled water): Refill, Low and High Range Comparators, Activator
Chlorine (free & total) Vacu-vials Kit (USEPA Approved) K-2513
Solution, Neutralizer Solution, dilutor snapper cup, micro test tube, instructions,
Kit comes in a cardboard box and contains everything needed to perform
and MSDS.
30 tests: thirty ampoules, Activator Solution, 25 mL sample cup, ampoule
blank, instructions, calibration table, and MSDS.
Range: 0-1000 & 1000-5000 ppm
MDL: 100 ppm / Method: DDPD
Cat#
SAM Single-Analyte Photometer
Chlorine (free & total) VACUettes Kit K-2505C
(See page 15 for instrumental features)
VACUettes Refill, 30 ampoules R-2505C
Range: 0.40-5.00 ppm
Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years A-2500
1
Method: DPD
Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-2501
1
Cat#
Low Range Comparator, Shelf-life 2 years:
Chlorine (free & total) SAM Kit I-2001
0, 100, 200, 300, 400, 600, 800, 1000 ppm C-2501C
Vacu-vials Kit, 30 ampoules, Activator Solution, 25 mL sample cup, ampoule
High Range Comparator, Shelf-life 2 years:
1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 ppm C-2505C
blank, instructions, calibration table, and MSDS. K-2513
Kit comes in a plastic case and contains everything needed to perform 30 tests
SAM Kit comes in a plastic case and contains everything needed to perform
(except distilled water): Refill, Low and High Range Comparators, Activator 30 tests: Vacu-vials Kit, SAM Photometer, 2 AA batteries, and instructions.
Solution, Neutralizer Solution, dilutor snapper cup, micro test tube, instructions,
and MSDS.
Vacu-vials Kits require the use of the V-2000 Photometer, or a spectrophotometer
capable of accepting a 13 mm diameter round cell. Instrument sold separately.
1
The accessory pack supplies enough solution to perform at least 200 tests.
Range: 0.3-1.6% as NaOCl The Activator Solution, A-2500, is used to determine Total Chlorine.
MDL: 0.3% / Method: DDPD
Cat#
Kit Components common to Chlorine
Chlorine (hypochlorite) VACUettes Kit K-5805
Description Cat#
VACUettes Refill, 30 ampoules R-5805 Sample Cup Pack, 25 mL (6 ea) A-0013
Comparator, Shelf-life 2 years:
Micro Test Tube Pack (10 ea) A-0015
0.3, 0.45, 0.6, 0.75, 0.95, 1.15, 1.3, 1.45, 1.6% C-5805
Dilutor Snapper Cup Pack (6 ea) A-0018
Ampoule Blank Pack (5 ea) A-0023
Kit comes in a plastic case and contains everything needed to perform 30 tests
Syringe Pack, 1.0 mL (6 ea) A-0027
(except distilled water): Refill, Comparator, 25 mL sample cup, dilutor snapper
cup, 1.0 mL syringe, micro test tube, instructions, and MSDS.
Instructions are posted on our website.
If no shelf-life is listed for a product, then the shelf-life is at least 2 years.
27
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88