This page contains a Flash digital edition of a book.
www.chemetrics.com | 1-800-356-3072
Range: 0-60 & 60-300 ppm Range: 2.5-12% as NaOCl
MDL: 10 ppm / Method: DDPD MDL: 2.5% / Method: DDPD
Cat# Cat#
Chlorine (free & total) VACUettes Kit K-2505A Chlorine (hypochlorite) VACUettes Kit K-5812
VACUettes Refill, 30 ampoules R-2505A VACUettes Refill, 30 ampoules R-5812
Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years A-2500
1
Comparator, Shelf-life 2 years:
2.5, 3.5, 4.5, 6.0, 7.0, 8.5, 9.5, 10.5, 12.0% C-5812
Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-2501
1
Kit comes in a plastic case and contains everything needed to perform 30 tests
Low Range Comparator, Shelf-life 2 years:
(except distilled water): Refill, Comparator, 25 mL sample cup, dilutor snapper
0, 10, 15, 20, 30, 40, 50, 60 ppm C-2501A
cup, 1.0 mL syringe, micro test tube, instructions, and MSDS.
High Range Comparator, Shelf-life 2 years:
60, 90, 120, 150, 175, 200, 225, 250, 300 ppm C-2505A
Kit comes in a plastic case and contains everything needed to perform 30 tests
(except distilled water): Refill, Low and High Range Comparators, Activator
Instrumental Kits
Solution, Neutralizer Solution, dilutor snapper cup, micro test tube, instructions,
and MSDS.
V-2000 Multi-Analyte Photometer
(See page 12 for instrumental features)
Range: 0-120 & 120-600 ppm
MDL: 20 ppm / Method: DDPD
Range: 0.40-5.00 ppm
Cat#
Method: DPD
Chlorine (free & total) VACUettes Kit K-2505B
Cat#
VACUettes Refill, 30 ampoules R-2505B
Chlorine (free) Vacu-vials Kit (USEPA Approved) K-2523
Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years A-2500
1
Kit comes in a cardboard box and contains everything needed to perform
Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-2501
1 30 tests: thirty ampoules, 25 mL sample cup, ampoule blank, instructions,
calibration table, and MSDS.
Low Range Comparator, Shelf-life 2 years:
0, 20, 30, 40, 60, 80, 100, 120 ppm C-2501B
Range: 0.40-5.00 ppm
High Range Comparator, Shelf-life 2 years:
Method: DPD
120, 180, 240, 300, 350, 400, 450, 500, 600 ppm C-2505B
Cat#
Kit comes in a plastic case and contains everything needed to perform 30 tests
(except distilled water): Refill, Low and High Range Comparators, Activator
Chlorine (free & total) Vacu-vials Kit (USEPA Approved) K-2513
Solution, Neutralizer Solution, dilutor snapper cup, micro test tube, instructions,
Kit comes in a cardboard box and contains everything needed to perform
and MSDS.
30 tests: thirty ampoules, Activator Solution, 25 mL sample cup, ampoule
blank, instructions, calibration table, and MSDS.
Range: 0-1000 & 1000-5000 ppm
MDL: 100 ppm / Method: DDPD
Cat#
SAM Single-Analyte Photometer
Chlorine (free & total) VACUettes Kit K-2505C
(See page 15 for instrumental features)
VACUettes Refill, 30 ampoules R-2505C
Range: 0.40-5.00 ppm
Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years A-2500
1
Method: DPD
Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-2501
1
Cat#
Low Range Comparator, Shelf-life 2 years:
Chlorine (free & total) SAM Kit I-2001
0, 100, 200, 300, 400, 600, 800, 1000 ppm C-2501C
Vacu-vials Kit, 30 ampoules, Activator Solution, 25 mL sample cup, ampoule
High Range Comparator, Shelf-life 2 years:
1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000 ppm C-2505C
blank, instructions, calibration table, and MSDS. K-2513
Kit comes in a plastic case and contains everything needed to perform 30 tests
SAM Kit comes in a plastic case and contains everything needed to perform
(except distilled water): Refill, Low and High Range Comparators, Activator 30 tests: Vacu-vials Kit, SAM Photometer, 2 AA batteries, and instructions.
Solution, Neutralizer Solution, dilutor snapper cup, micro test tube, instructions,
and MSDS.
Vacu-vials Kits require the use of the V-2000 Photometer, or a spectrophotometer
capable of accepting a 13 mm diameter round cell. Instrument sold separately.
1
The accessory pack supplies enough solution to perform at least 200 tests.
Range: 0.3-1.6% as NaOCl The Activator Solution, A-2500, is used to determine Total Chlorine.
MDL: 0.3% / Method: DDPD
Cat#
Kit Components common to Chlorine
Chlorine (hypochlorite) VACUettes Kit K-5805
Description Cat#
VACUettes Refill, 30 ampoules R-5805 Sample Cup Pack, 25 mL (6 ea) A-0013
Comparator, Shelf-life 2 years:
Micro Test Tube Pack (10 ea) A-0015
0.3, 0.45, 0.6, 0.75, 0.95, 1.15, 1.3, 1.45, 1.6% C-5805
Dilutor Snapper Cup Pack (6 ea) A-0018
Ampoule Blank Pack (5 ea) A-0023
Kit comes in a plastic case and contains everything needed to perform 30 tests
Syringe Pack, 1.0 mL (6 ea) A-0027
(except distilled water): Refill, Comparator, 25 mL sample cup, dilutor snapper
cup, 1.0 mL syringe, micro test tube, instructions, and MSDS.
Instructions are posted on our website.
If no shelf-life is listed for a product, then the shelf-life is at least 2 years.
27
Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88
Produced with Yudu - www.yudu.com. Publish online for free with YUDU Freedom - www.yudufreedom.com.