This page contains a Flash digital edition of a book.
Ammonia
www.chemetrics.com | 1-800-356-3072
Methods
Low-level ammonia nitrogen may be naturally present
The Salicylate Method offers similar sensitivity to the
in water as a result of the biological decay of plant and
Nesslerization Method and is available in both visual
animal matter. Higher concentrations in surface waters
and instrumental versions. The benefits that the
can indicate contamination from waste treatment facili-
Salicylate product line offers are that the shelf-life of
ties, raw sewage, industrial effluents (particularly from
the ampoules is unlimited and there is no generation of
petroleum refineries), or fertilizer runoff. Excessive
mercury-containing waste.
ammonia concentrations are toxic to aquatic life.
The Direct Nesslerization Method
Visual Kits
Reference: ASTM D 1426-03, Ammonia Nitrogen in
Range: 0-1 & 1-10 ppm
Water, Test Method A. APHA Standard Methods, 18
th
MDL: 0.05 ppm / Method: Direct Nesslerization
ed., pp. 4-78, Method 4500-NH
3
C (1992).
Cat#
The test kits employing the well-established Nessler
CHEMets Kit *K-1510
reagent* to determine ammonia concentrations are
CHEMets Refill, 30 ampoules, Shelf-life 5 months *R-1501
2
applicable to drinking water, clean surface water, good-
Stabilizer Solution Pack, six 10 mL bottles, Shelf-life 2 years A-1500
1
quality nitrified wastewater effluent, and seawater. Stabilizer Solution Pack, six 70 mL bottles, Shelf-life 2 years A-1501
1
In some waters, calcium and magnesium concentrations Low Range Comparator, Shelf-life 2 years:
can cause cloudiness of the reagent. Adding a few
0, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0 ppm C-1501
drops of stabilizer solution (Rochelle Salt) will prevent
High Range Comparator, Shelf-life 2 years:
1, 2, 3, 4, 5, 6, 7, 8, 10 ppm C-1510
this cloudiness. References recommend distilling
Kit comes in a plastic case and contains everything needed to perform
samples prior to analysis. Results are expressed as 30 tests: Refill, Low and High Range Comparators, Stabilizer Solutions,
ppm (mg/L) ammonia-nitrogen, NH
25 mL sample cup, 1.0 mL syringe, instructions, and MSDS.
3
-N.
Shelf-life: although the Nessler reagent is stable,
its high alkali content attacks the glass ampoule.
Range: 0-2 & 0-20 ppm
MDL: 0.05 ppm / Method: Salicylate
The resulting precipitate interferes with color compari-
Cat#
son. We recommend stocking quantities of CHEMets
®
CHEMets Kit K-1410
and VACUettes
®
ampoules that will be used within five
CHEMets Refill, 30 ampoules R-1401
months. A two-month supply of Vacu-vials ampoules is
Activator Solution Pack, six 20 mL bottles, Shelf-life 8 months A-1400
1
suggested. Refrigeration will dramatically extend the
shelf-life of these products.
Catalyzer Solution Pack, six 20 mL bottles, Shelf-life 2 years A-1401
1
*Contains mercury. Dispose according to local, state or federal laws.
Comparator, Shelf-life 2 years:
0, 0.25, 0.50, 0.75, 1.0, 1.25, 1.5, 1.75, 2.0 ppm C-1402
The Salicylate Method
Kit comes in a plastic case and contains everything needed to perform 30 tests
(except distilled water): Refill, Comparator, Activator Solution, Catalyzer
References: Krom, Michael D., Spectrophotometric
Solution, 25 mL sample cup, 3.0 mL syringe, instructions, and MSDS.
Determination of Ammonia: A Study of a Modified
Berthelot Reduction Using Salicylate and
Range: 0-30 & 30-300 ppm
Dichloroisocyanurate, The Analyst, V105, pp. 305-316,
MDL: 5 ppm / Method: Direct Nesslerization
1980.
Cat#
In the ammonia test method that employs the Salicylate VACUettes Kit *K-1510D
chemistry, free ammonia reacts with hypochlorite to VACUettes Refill, 30 ampoules, Shelf-life 5 months *R-1501D
2
form monochloramine. Monochloramine reacts with
Low Range Comparator, Shelf-life 2 years:
salicylate, in the presence of sodium nitro-ferricyanide,
0, 5, 7.5, 10, 15, 20, 25, 30 ppm C-1501D
to form 5-aminosalicylate, a green-colored complex.
High Range Comparator, Shelf-life 2 years:
30, 60, 90, 120, 150, 175, 200, 250, 300 ppm C-1510D
This test method measures free ammonia and mono-
Kit comes in a plastic case and contains everything needed to perform
chloramine. Results are expressed in ppm (mg/L) ammo-
30 tests (except distilled water): Refill, Low and High Range Comparators,
nia-nitrogen, NH
dilutor snapper cup, micro test tube, instructions, and MSDS.
3
-N.
*Contains mercury. Dispose according to local, state or federal laws.
18
Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88
Produced with Yudu - www.yudu.com. Publish online for free with YUDU Freedom - www.yudufreedom.com.