AirUser 2008 96+4pp 23/7/08 16:51 Page 58
SECTION 6
Energy
Management &
Instrumentation
Manage capacity and
reduce compressed air costs
with the New Testo 6440 Compressed Air Flow Meter
Compressed air is a costly resource. If an
organisation has no knowledge of
compressed air consumption by department,
Company name
process or machine it can make cost
Testo Ltd
allocation difficult and does not motivate the
organisation to look at methods to reduce
Address
leakage or consumption. The new Testo 6440
Newman Lane
is a compressed air flow meter that enables
Alton
organisations to accurately monitor
Hampshire
compressed air usage to assist in managing
GU34 2QJ
costs and planning resource allocation.
Contact details
SUPERIOR DESIGN FOR ACCURATE
Tel: 01420 544433
MEASUREMENTS
The Testo 6440 measures mass flow to guarantee
Fax: 01420 544434
correct measurements and is unaffected by the effect of
airuser@testo.co.uk
fluctuating pressure conditions and temperatures. In
www.testo.co.uk four diameter sizes, the Testo 6440 offers a compact
design coupled with integrated high-performance
Literature
technology, which provides all necessary signal outputs.
Comprehensive
The built-in inflow and outflow pipes guarantee
optimum accuracy and the thermal glass coated ceramic
technical product
sensor offers robustness and fast reaction times.
literature available
on request. Please
LOWERING COSTS BY CONSUMER
call our technical
ALLOCATION
sales team on The Testo 6440 can be used to measure the
01420 544433.
consumption of compressed air by individual
department, process or machine. When compressed air
Other Products
consumption of each system is recorded individually in
Wide range of portable
this way, the person responsible for the system is
and stationary
motivated to reduce leakage and to employ
instrumentation
consumption-saving measures. The Testo 6440 provides
covering a range of
optimal support here, with a built-in totaliser function.
parameters including:
The total consumption can be read directly from the
- Temperature
instrument or registered in the regulating system via
- Humidity consumption impulses. Consumption-dependent switch
- Velocity outputs are alternatively also available, which can load analysis on the basis of compressed air counters
- Pressure monitor maximum consumption either time-
can help to avoid such investments. By knowing when
- Emissions monitoring
dependently or time-independently. consumption occurs, the existing and planned
- Refrigeration
consumption can be distributed over a daily / weekly
- Flue gas
LEAKAGE DETECTION profile so that the existing capacity of compressed air
- Water analysis
Over 96% of leakages occur in DN50 (2”) pipes and production is sufficient. The result is considerable
- Light
smaller. Leaky hoses, fittings, connections and savings in the compressors as well as in the pipe system.
maintenance units are mainly responsible for this.
Standards
Installed in front of an individual machine or a machine MANAGE COMPRESSED AIR SUPPLY TO
ISO 9001:2000 group, the Testo 6440 can detect even the smallest
ENSURE PRODUCT QUALITY AND PROTECT
UKAS
compressed air volume flows and can indicate any
EQUIPMENT
leakage occurred during machine downtime.
It may be necessary for a continuous minimum or
Further maximum compressed air supply to be maintained in
information
PEAK LOAD MANAGEMENT HELPS TO
order to ensure product quality or protect equipment.
Please contact
AVOID EXTENDED INVESTMENTS The Testo 6440 performs both monitoring tasks
Growth can be expensive, forcing industrial enterprises
Peter Sullivan on
effectively thanks to its two switch outputs, ensuring
to also expand their compressed air production. Peak the continuous protection of your investment.
01420 544433
Testo 6740 Pressure Dew Point Transmitter
Testo also offer the Testo 6740 pressure dew point transmitter which efficiently
measures pressure dew point in compressed air or dry air/gas to help protect
your compressed air system from moisture damage, therefore reducing
maintenance costs.
0805
The Testo 6740 offers; reliability, calculation of ˚Ctpd, ˚Ctd atmospheric
ENTER 81804
and ppmv, pressure tight connection (up to 50 bar) and easy-to-use
www.airuser.com/enquiry
menu operation
58 AirUser
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100